Csi specification for fire rated materials
Web1.1.14 Multiple Component Firestop System; means a group of Firestop Materials that are used within a Listed Systems Design to create a Firestop System. 1.1.15 Smoke Seal; … WebN/A. download csi specs. Fireframes® Heat Barrier Series - BR. 08 41 23 - Steel Framed Entrances & Storefronts. Fireframes TimberLine ® Series. 45/60/120 Minutes. Features …
Csi specification for fire rated materials
Did you know?
Web06448 Porch, Post and Railings. 06060 Recycled Wood Material. 06180 Glue Laminated structures. 06450 Wood Trim, Corbels, Fascias + Soffits. 06065 Plastic Laminates + Countertops. 06200 Wood Finish Carpentry: Millwork + Trim. 06460 Wood Door Jambs + Frames. 06070 Fire-Retardant Treatment Wood. 06250 Wood Paneling + Veneers. Webspecification in CSI 3-part format. SECTION 06 40 00 ... 1. Fire Retardant Treatment Data: Submit fire retardant treatment data for material treated to reduce combustibility. FOR …
WebFire Rating: Fire rating classified and labeled by UL for fire rating scheduled at opening locations on drawings, when tested in accordance with [ASTM E2010-01] [ULC … Web1.1.14 Multiple Component Firestop System; means a group of Firestop Materials that are used within a Listed Systems Design to create a Firestop System. 1.1.15 Smoke Seal; means an elastomeric sealant material that has been used for a Single Component Firestop System and that has a ASTM E-84 flame spread rating of 25 or less. 1.1.16 Tightly …
WebInstitute (CSI) and Construction Specifications Canada (CSC). Contents reflect MasterFormat titles and numbers as of April 2016. Consult ... 00 31 26 Existing Hazardous Material Information 00 31 26.23 Existing Asbestos Information 00 31 … WebC. Test for fire endurance in accordance with ASTM E119, for fire rating specified, in a nationally recognized laboratory. D.Manufacturer's inspection and approval of surfaces to receive fireproofing. E.Manufacturer's approval of fireproofing applications. F.Manufacturer's approval of completed installation.
WebA. Fire-Test-Response Characteristics: For fireresistance-rated assemblies that incorporate non- - load-bearing steel framing, provide materials and construction identical to those tested in assembly indicated, according to ASTME 119 by an independent testing agency.
WebAug 1, 2011 · Openings - Building material and construction product manufacturers organized by the product or the material into CSI master format divisions. Explore the … early east tennessee settlersWebThis guide specification is a supplier-specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. This Section specifies the “Fireframes® Aluminum Series” a fire-rated steel frame system supplied by Technical Glass Products further described in ... early eastern kentucky historyWebThis guide specification is a supplier-specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide … early east thames valley parkWebOct 17, 2024 · Fire Rating: Fire rating classified and labeled by UL for fire rating scheduled at opening locations on drawings, when tested in accordance with [ASTM … early eastenders charactersWebspecification in CSI 3-part format. SECTION 06 40 00 ... 1. Fire Retardant Treatment Data: Submit fire retardant treatment data for material treated to reduce combustibility. FOR LEED® PROJECTS INCLUDE THE FOLLOWING, AS APPLICABLE. ... added urea-formaldehyde resins as outlined in LEED® Green Building Rating System. 1.5 QUALITY … early eastenders castWebin The CSI Construction Specifications Practice Guide. ... C. California Department of Forestry and Fire Protection (CAL FIRE) (www.fire.ca.gov): 1. Wildland-Urban Interface (WUI) CA SFM 12.7A-1 – Exterior Wall Siding and Sheathing. ... 2. Material: Polymeric blend, fly ash, and glass fibers. 3. Formed in continuous process, cut to 16-foot ... early eastwood roleWebExterior Specialties. Specialties add to the asthetics of the building, protect people and the building from the weather, and flag poles. 10 71 00. Exterior Protection. 10 71 13. … cst cfop 5125